24/7 Emergency Service Licensed & Insured · License B31188501 Financing Available Serving All of Dallas–Fort Worth
Maglock Repair

Magnetic Lock Repair in Dallas–Fort Worth

Maglock not releasing, not holding or not re-locking after a fire alarm? A1 repairs magnetic locks on any brand, including systems another company installed, with 24/7 emergency service.

Magnetic Lock Repair for Commercial Doors and Gates

A maglock that will not release can keep people from getting out. A maglock that will not hold leaves the door unsecured. Both are urgent, and both are problems we fix. A1 Security Gate & Intercom repairs electromagnetic locks on glass storefronts, office suites, stairwell and lobby doors, and pedestrian gates across Dallas–Fort Worth.

The magnet itself is rarely the part that fails. A maglock is one piece of a circuit that also includes the power supply, the request-to-exit (REX) motion sensor, the push-to-exit button, the fire alarm release relay and the access control panel. Our technicians test that whole circuit, so the fix lasts instead of coming back next month.

Common Maglock Problems and What They Usually Mean

Maglock Not Releasing or Door Not Opening

Maglocks are fail-safe: they hold only while they have power. If the door stays locked when someone badges in or walks up to exit, something is still feeding power to the lock. The usual causes are a REX motion sensor that is aimed wrong or has failed, an access controller relay that is stuck or wired to the wrong contact, a push-to-exit button that no longer breaks the circuit, or a power supply relay with welded contacts.

If the door releases but sticks for a second or two, the cause is often residual magnetism. A slight magnetic charge stays in the core after power drops, and the armature hangs on. Worn rubber washers, an armature bolted down too rigidly, or an aging lock make it worse. Spraying lubricant on the faces or prying the door will not fix it and can damage the plate.

Maglock Not Holding or Door Pulls Open

A maglock only reaches its rated holding force when the armature plate sits flat against the full face of the magnet. If the door can be pulled open, we look for:

  • An armature that is misaligned, so only part of the plate touches the magnet
  • Missing or crushed rubber washers that let the plate float and self-align
  • Dirt, rust, paint or a sticker between the two faces
  • The wrong voltage setting (12V vs. 24V) or voltage drop on a long wire run
  • A door that does not close fully because of a weak closer, sagging hinges or worn pivots
  • A power supply or backup battery that can no longer carry the load

Maglock Not Engaging or Not Locking at All

When the door never locks, the lock usually has no power. Common reasons are a blown fuse on the power supply, a tripped breaker, a fire alarm input that never reset after a test, an access schedule left on unlock, or wiring cut during a remodel. A failed coil is possible too, especially on a lock that ran at the wrong voltage and overheated.

Maglock Won't Re-Lock After a Fire Alarm or Power Outage

Maglocks on egress doors are tied to the fire alarm so they drop when the alarm goes off. Some lock power supplies, including Altronix models with a fire alarm interface, can be set to latch: the locks stay released until someone resets the input after the panel clears. If the locks stayed open after a drill or an outage, the fix is often at the power supply or the fire alarm relay, not at the door.

Door Shows Forced or Held-Open Alarms

Many maglocks have a built-in bond sensor that reports whether the armature is fully seated. If the plate is slightly out of line, the bond sensor reports an unsecured door and the access system logs forced or held-open alarms, even though the door looks closed. Re-aligning the armature or replacing a failed sensor clears it.

Commercial electromagnetic maglock with its armature plate mounted on a glass door header
Example: a maglock and armature plate on a glass door header. The plate has to sit flat against the full face of the magnet to hold.

What We Check and Fix on a Maglock Repair Visit

  • Armature alignment, mounting hardware, rubber washers and the condition of both faces
  • Measured voltage at the lock, with the door locked and under load
  • Power supply output, fuses, backup batteries and the fire alarm interface
  • REX motion sensor aim and timing, plus the push-to-exit button
  • Fire alarm release relay and the lock re-arming after the panel resets
  • Bond sensor and door position reporting to the access control system
  • Access controller relay, door schedule and wiring to the door
  • Replacement locks sized for the opening, typically 600 lb or 1,200 lb holding force

Safe Things to Check Before You Call

A few quick checks can save time, and none of them require opening a panel:

  • Is the light on the power supply on? Did a breaker trip?
  • Was there a fire alarm test, power outage or construction work recently?
  • Wipe both magnet faces with a dry cloth. Do not use oil or cleaner on them.
  • Watch the door close. Does it close all the way on its own?
  • Never chain, tape or block an exit door to work around a bad maglock.

If a maglock will not release and people cannot get out, use another exit and call us right away. Call 911 if anyone is in danger.

Maglock Brands We Repair, Including Systems Other Companies Installed

We repair systems installed by other companies, and we work on all brands. That includes maglocks from Securitron, Seco-Larm and Alarm Controls, Altronix power supplies, and access control systems from HID, Keyscan, UniFi Access, Brivo, Paxton and others. If the original installer is gone or no longer answers, we can trace the wiring, label it and get the door working. If the maglock is part of a larger problem, our access control repair team handles the panel and readers too.

Magnetic lock mounted on a steel pedestrian gate post
Example: a maglock on a pedestrian gate. Outdoor maglocks need weather-rated hardware and solid alignment to hold.

Repair or Replace?

Most maglock calls end in a repair: an alignment, a sensor, a power supply part or a wiring fix. Replacement makes sense when the coil has failed, the housing or bond sensor is damaged, or the lock is too small for the door. Sometimes the better answer is a different lock. A fail-secure electric strike can suit doors that do not need to release on power loss; see our electric strike repair page. If you are adding new doors or replacing several locks, our magnetic lock installation service includes free estimates and a 1-year workmanship warranty.

How a Maglock Repair Visit Works

1

Call or Request a Visit

Tell us what the door is doing and when it started. Service calls start at $180 per hour.

2

Diagnose the Circuit

We test the lock, armature, power supply, REX, fire alarm release and controller.

3

Repair on the Spot

Most fixes, like alignment, sensors, fuses and wiring, are done during the visit.

4

Test Every Mode

We check badge release, free exit, fire alarm drop and re-lock before we leave.

24/7 Emergency Maglock Service

A door that will not lock at closing time, or one that will not let people out, cannot wait until Monday. We offer 24/7 emergency service and same-day service when the schedule allows. Call (682) 516-9940 or request a repair visit online. If the door also has panic hardware that is acting up, see panic bar repair.

We repair magnetic locks for businesses, apartments, HOAs, clinics and property managers in Dallas, Plano, Frisco, Allen, McKinney, Richardson, Irving, Garland, Carrollton and Fort Worth, plus the surrounding North Texas cities.

Explore More

Related Services

Local Coverage

Magnetic Lock Repair Across DFW

A1 repairs maglocks, REX sensors and lock power supplies for businesses and properties throughout Dallas–Fort Worth and North Texas.

View All Service Areas
Answers

Frequently Asked Questions

Common questions about magnetic lock repair in Dallas–Fort Worth.

Why is my maglock not releasing?
A maglock releases only when its power is cut, so a door that stays locked usually means power is still reaching the lock. The most common causes are a failed or misaimed REX motion sensor, a stuck access controller relay, a push-to-exit button that no longer breaks the circuit, or a power supply relay that has failed. If the door releases but sticks for a moment, residual magnetism or a worn armature mount is the likely cause.
Why is my magnetic lock not holding the door?
Most often the armature plate is out of line with the magnet, so only part of the face makes contact. Dirt or rust on the faces, missing rubber washers, the wrong voltage setting, a weak power supply or a door that does not close fully can also cut holding force. We measure voltage at the lock and re-align the armature to restore full hold.
Do you repair maglocks that another company installed?
Yes. We repair systems installed by other companies and work on all brands, including Securitron, Seco-Larm and Alarm Controls maglocks with Altronix power supplies. If the old installer left no documentation, we trace and label the wiring as part of the repair.
How much is a maglock repair service call?
Service calls start at $180 per hour, and the technician diagnoses the problem first. Parts and any additional work are quoted before we do them, so you know the cost first.
Why didn't my maglocks re-lock after a fire alarm?
Maglocks on egress doors are tied to the fire alarm so they release during an alarm. Many lock power supplies use a latching fire alarm input that must be reset after the panel clears. If the locks stay open after a drill or outage, the fix is usually at the power supply or fire alarm relay, and we can test and reset it.
Is maglock repair available 24/7?
Yes. We offer 24/7 emergency service for maglocks that will not lock or will not release. Call (682) 516-9940 any time, and we provide same-day service when the schedule allows.

Get Your Maglock Working Again

Call for 24/7 emergency maglock repair anywhere in Dallas–Fort Worth. Service calls start at $180 per hour, with same-day service when the schedule allows.

Call Now